CFP Alarmsense Fire Panel

Conventional systems

Most conventional fire systems are designed to work with two pairs of wires per zone: one pair for detection devices
such as smoke detectors, heat detectors and manual call points; the other for alarm devices such as bells, sounders or
strobes. By using different voltage bands for quiescent and alarm states, AlarmSense® components can be connected
to the same pair of supply wires.
When powered and controlled by the CFP two-wire fire panel, this reliable technology takes all the complexity out of fire
alarm system design, leading to quicker, less expensive and more flexible installation. Research shows an AlarmSense®
two-wire system can achieve a 20-25% reduction of labour over a standard four wire conventional system.
AlarmSense® devices are acceptable for BS 5839-1 and BS 5839-6 systems making them particularly useful for fire
protection in Houses of Multiple Occupation (HMOs).

 

Key Features:

  • Designed to comply with EN54 Parts 2 and 4
  • Available with 2, 4 or 8 AlarmSense zone circuits (dependent on model purchased)
  • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry to access level 2
  • Four conventional sounder circuits (for use with non-AlarmSense sounders)
  • Integral 1.5A EN54-4/A2 compliant switch mode PSU
  • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones
  • Two on-board relays (Fire and Fault)
  • Two open-collector outputs (Remote and Reset)
  • ‘Class change’ and alert inputs
  • Installer-friendly design accommodates easy first fix and straightforward maintenance
  • Attractive flush or surface mountable plastic lid and enclosure - no bezel required
  • Low quiescent current
  • Multiple indicators
  • End of line units included (one per zone)
  • Ancillary system expansion connections provided for up to eight two-wire repeaters (one CFP761 network driver card required per system) and optional CFP relay boards
  • Space for two x 12V 3.2Ah VRLA batteries
  • Third-party LPCB tested

For full spec click here


CFP 2-8 Zone LPCB Fire Panel

CFP 2-8 Zone LPCB Fire Panel

C-TEC's award-winning CFP conventional fire panel is LPCB certified to the latest revisions of EN54 parts 2 and 4 and offers an array of user and installer-friendly features at a very competitive price. Supplied in an attractive flush or surface mountable plastic enclosure, 2, 4 and 8 zone versions are available, each featuring four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry. A wide range of engineering functions are also provided including selectable zone delays, coincidence and non-latching zone facilities. Comprehensive test and fault finding facilities are also provided.

Key Features:

  • LPCB certified to the latest versions of EN54 Parts 2 and 4
  • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry to access level 2
  • 2, 4 or 8 zone circuits (dependent on model purchased)
  • Four conventional sounder circuits
  • Integral 1.5A EN54-4/A2 compliant switch mode PSU
  • Wide range of engineering functions including zone test, coincidence*, zone delay and non- latching zones*
  • Two on-board relays (Fire and Fault)
  • Two open-collector outputs (Remote and Reset)
  • ‘Class change’ and alert inputs
  • Installer-friendly design accommodates easy first fix and straightforward maintenance
  • Attractive flush or surface mountable plastic lid and enclosure - no bezel required
  • Low 25mA quiescent current
  • Multiple indicators
  • End of line units included (one per zone)
  • Ancillary system expansion connections provided for up to eight two-wire repeaters (one CFP761 network driver card required per system) and optional CFP relay boards
  • Space for two x 12V 3.3Ah VRLA batteries

For full spec click here